SIMATIC WinCC 7.3 – SIMATIC WinCC 7.3 V7.2 – V7.3 WinCC V7.2 WinCC 7.3 Windows 8.1 Server 2012 UNICODE SSL (PSK) ) . Configuration Studio - Configuration Studio – Graphics Designer - Graphics Designer S7-1200 & S71500 S7-1200 & S7-1500 (Tag & Alarm browsing; ) . OPC UA Server 18.… .2 WinCC/WebUX ( WinCC OPC UA Server (A&E) … .) SIMATIC WinCC 7.3 • Windows 7 SP1 32-Bit 64-Bit (Business / Enterprise / Ultimate) • Windows 8.1 32-Bit 64-Bit (Professional / Enterprise)* • Windows Server 2008 R2 SP1 64-Bit • Windows Server 2012 R2 64-Bit* • Windows Embedded Standard 7 o ! IPC ES Products Released Windows XP Professional Windows Server 2003 R2 SQL Server 2005 .3 Lifecycle Start Date 12/31/2001 3/5/2006 1/14/2006 Mainstream Support End Date 4/14/2009 7/13/2010 4/12/2011 Extended Support End Date 4/14/2014 7/14/2015 4/12/2016 Service Pack Support End Date 8/30/2005 4/14/2009 07/10/2007 SIMATIC WinCC 7.3 Windows 7 SP1 * 32 Bit Windows 7 SP1 * 64 Bit Windows 8.1 32 Bit / 64 Bit Windows Server 2008 R2 SP1 64 Bit Windows Server 2012 R2 64 Bit X X X X X X x x X X X** X** X** X X Web/DM*** Server X*** X*** X*** X X Web/DM*** Client X X X X X Single User X * X X * * . *Windows Embedded Standard 7 *) Professional / Enterprise / Ultimate **) 3WinCC ***) Web/DM = WebNavigator/DataMonitor Server Web/DM WinCC WinCC .4 3- Windows SIMATIC WinCC 7.3 Windows 7 SP1 32 Bit / 64 Bit Windows 8.1 32 Bit / 64 Bit Windows Server 2008 SP2 32 Bit / R2 SP1 64 Bit Windows Server 2012 R2 64 Bit CPU Dual Core-CPU; 3,5 GHz (ab Core i3) Multi Core-CPU; 2,4 GHz (Core i3/i5/i7) RAM 4 GByte 4 GByte CPU Dual Core-CPU; 3 GHz (ab Core i3) - RAM 4 GByte - Single-User Client CPU Multi Core-CPU; 2,4 GHz (Core i5/i7) RAM 8 Gbyte CPU Multi Core-CPU; 2,4 GHz (Core i5/i7) RAM 8 Gbyte CPU ab Dual Core-CPU´s , AMD Athlon 64 RAM 4 GByte Server Web/DM Server Web/DM Client .5 SIMATIC WinCC 7.3 SIMATIC WinCC "Windows on Windows64“ • .Net Framework 3.5 & 4.0 . • SIMATIC WinCC 64- SQL Server 2008 32WinCC • SIMATIC WinCC WinCC 7.3 Microsoft Office 32- * Office 2013 New in V7.3 • SIMATIC WinCC Internet Explorer 11 • SIMATIC WinCC ESXi 5.5 & HyperV 2012 * WinCC Data Monitor/Information Server .6 Microsoft Excel SIMATIC WinCC 7.3 • SIMATIC Net V12 • WinCC WebUX • SIMATIC Information Server WinCC DVD CD/DVD • SQL Server 2008 R2 SP2 (32bit) .7 SIMATIC WinCC 7.3 • WinCC "C:\Program Files (x86)\Siemens\WinCC\bin\CCMigrator.exe„ V6.2 SP3 * V7.0 V7.0 SP1/SP2/SP3 * V7.2 ) *V6.2 , , .8 .. SIMATIC WinCC 7.3 • SIMATIC WinCC V6.2 / V7.0 => V7.3 V7.2 => V7.3 . Server, Redundancy, UserArchives, ConnectivityPack, ConnectivityStation, WebNavigator DataMonitor . WinCC V6.2) WinCC V7.3 V6.2 .9 WinCC 7.3 Configuration Studio : • Alarm Logging Tag Logging Text Library User Administrator User Archive Horn • • , . 10 WinCC 7.3 Configuration Studio Configuration Studio 1. ) 2. 3. ” 4. ” 5. “ 6. / ”/” (*.txt & *.xlsx / Configuration Tool) . 11 ” Tag Management: WinCC 7.3 Configuration Studio Alarm Logging: • Configuration Studio • : 1. , , 2. . 12 . WinCC 7.3 Configuration Studio Tag Logging: • Configuration Studio • : • . 13 WinCC 7.3 Graphics Designer : „process pictures“ Drag & Drop faceplates , faceplates picture window „ “ (pdl / fpt) : User Administrator Control . 14 WinCC 7.3 Graphics Designer „Output window“: : Direct2D ( SVG Graphics) GraCS . 15 ) (Scalable Vector WinCC 7.3 Graphics Designer : “display name" . Dynamic script function "DisplayName" .” . : WinCC “Dark” . . 16 WinCC 7.3 • SSL PSK SIMATIC Shell SIMATIC HMI) PSK • TCP/UDP 1024 – 65535. , ) • . . 17 WinCC 7.3 SIMATIC Manager • • .* Clients 1..32 1..18 WinCC Server OS ) WinCC V7.3 WinCC V7.3 e.g. WinCC Server A e.g. WinCC Server A z.B. Alarm Logging z.B. Tag Logging ES 1 WinCC (Single-user, multi-user and client with own project) User Administrator ES 2 ES . 18 . WinCC 7.3 • Multiuser-Engineering Configuration Studio . . 19 WinCC 7.3 • Remote-configuration ( ) Multiuser-Engineering . . User User Administrator Administrator Interconnect SIMATIC Shell Open Shell Windows . SIMATIC HMI . 20 SIMATIC WinCC 7.3 S7-1200 • S7-1500 S7-1200 S7-1500 Clients New in V7.3 WinCC Server 1 .. 50 1 .. 18 (program alarm) AS (S7-1500) & S7-1200/S7-1500 WinCC / 1) TIA Portal ) 2) WinCC Configuration Studio AS ) New in V7.3 . 21 S7-1500 WinCC WinCC 7.3 S7 1500 • . 22 S7-1200/S7-1500 WinCC „Read from AS“ WinCC 7.3 S7 1500 • S7-1500 . 23 WinCC „Load from AS“ WinCC 7.3 – Scalability WinCC Plant Intelligence Energy Management Web Navigator / WebUX V7 DataMonitor V7 powerrate Qx Server V7 IndustrialDataBridge V7 B.Data Qx Process Historian Qx ConnectivityStation V7 System Expansions Telecontrol Qx ConnectivityPack V7 IndustrialX Qx ODK (Open Development Kit)* Qx High Availability Information Server Qx Redundancy V7 SCADA Extensions ProAgent Qx User Archives V7 Audit Qx Maintenance Station Qx Calendar Scheduler Qx Change Control Qx Event Notifier Qx Logon V7 Validation / Trace Qx V7 *ODK . 24 . IndustrialX WinCC V7.3 WinCC V7.3 WinCC 7.3 • Windows 8.1 Windows Server 2012 • • SSL • • • • Configuration Studio Graphics Designer S7-1200 & S7-1500 OPC UA Server (A&E) • • WinCC WebUX WebNavigator . 25 PSK